This page was exported from Actual Test Materials [ http://blog.actualtests4sure.com ] Export date:Fri Nov 15 19:37:18 2024 / +0000 GMT ___________________________________________________ Title: [Jan-2024] Latest HP HPE0-S60 Certification Practice Test Questions [Q32-Q50] --------------------------------------------------- [Jan-2024] Latest HP HPE0-S60 Certification Practice Test Questions Verified HPE0-S60 Dumps Q&As - 1 Year Free & Quickly Updates HP HPE0-S60 Certification Exam is a valuable credential for IT professionals who want to demonstrate their proficiency in HPE Compute Solutions. Delta - HPE Compute Solutions certification is recognized globally and is highly respected in the IT industry. Individuals who hold this certification are in high demand and can expect to receive a higher salary than their non-certified peers. Furthermore, this certification is a prerequisite for other advanced certifications in HPE Compute Solutions.   NEW QUESTION 32Match HPE SimpliVity team with the definition. NEW QUESTION 33Your customer manages HPE Synergy using HPE OneView. For one of its projects, the company purchased 50 HPE.ProLiant DK385 Gen10 Plus v2. They plan to manage the new systems using HPE OneView as well.What should the customer do to manage rack system using HPE OneView?  add the rack system to the HPE OneView instance used to manage HPE Synergy to centralize management of all systems.  connect the rack system to an IPDU and add the IPDU to the HPE. OneView instance that is used for HPE synergy management.  Deploy HPE OneView Global Dashboard and add the rack systems there, as AMD systems are not directly in HPE OneView.  Deploy an HPE OneView virtual appliance, and, after configuration, use it to manage only the rack systems. NEW QUESTION 34Your customer plans to expand an existing nPar based on a single HPE Superdome Flex chassis. Which statement about workload availability during expansion is true?  Powered nPar can be expanded only if HPE Superdome Flex 280 is used  Online expansion is available only if RMC is used for management.  HPE Superdome Flex does not support expansion of powered on nPars  Powered nPar can be expanded if it does not use HPE Persistent Memory NEW QUESTION 35Click the area within the iLO management interface that will allow you to access workload Advisor. NEW QUESTION 36Your customer experienced some problems caused by outdated HPE Superdome Flex firmware. Which update method should they use to avoid these issues in the future?  HPE OneView method for I/O firmware update procedure  RMC CLI to update I/O and HPE Persistent Memory firmware  HPE OneView IT HPE Persistent Memory firmware must be updated.  HPE SUM if HPE Persistent Memory firmware must be updated NEW QUESTION 37Put the steps of the HPE infosight flow in the correct order. 1 – Observing2 – Learning3 – Predicting4 – Recommending5 – ActingNEW QUESTION 38Click the option that will allow you to change the ESXI image used In an OS Deployment Plan. NEW QUESTION 39An HPE Synergy customer needs to prevent a timeout and loss of communication during an external switch firmware upgrade.Click the parameter that the customer should configure within an uplink set to meet this requirement NEW QUESTION 40Your customer has the following HPE Synergy setup:– 15 HPE Synergy 12000 frames with 50Gb connectivity to each server port– 2 HPE Composer 2 modules– 15 HPE D3940 Storage Modules, one per frame– 2 HPE 12Gb SAS switches per frameWhich statement about this setup is true?  The customer must create at least five logical enclosures for this setup.  To manage 15 frames, additional HPE Composers are required.  The customer can install up to 12 HPE Synergy 480 compute nodes per frame.  If properly cabled, any compute node can access any HPE D3490 storage module NEW QUESTION 41Your customer has experience with utilization sampling for HPE Virtual Connect SE 100 Gb F32 Module for HPE Synergy. They have recently purchased HPE VC FC modules.What must you be aware of regarding utilization sampling for the new modules?  Utilization sampling for HPE VC FC modules must be enabled manually using CLI.  For HPE VC FC modules, utilization sampling is always enabled and cannot be disabled  For HPE VC FC modules, utilization sampling can be enabled once appropriate license is applied  Utilization sampling works the same way tor any type of HPE Synergy interconnect modules NEW QUESTION 42Your customer plans to manage HPE Primera using HPE OneviewWhich storage management tasks can be completed using HPE OneView for this environment?  CPG management  Volume provisioning  Cache management  Replication setup NEW QUESTION 43Match HPE SimpliVity term with the definition. NEW QUESTION 44Which HPE Virtual Connect feature allows an administrator to suppress excessive inbound multicast broadcast and destination lookup failure (OLF) packets?  Pause flood protection  Loop protection  LLDP tagging  Storm control NEW QUESTION 45Your customer plans to deploy VMware ESXi 7. 0 U2, and they are looking for a hardware platform that will allow them to use up to 16 CPU sockets Which HPE compute system meets the customer requirements?  HPE ProLiant DL580 Gen10  HPE ProLiant OL380 Gen 10 Plus  HPE Synergy 480 Gen10 Plus  HPE Superdome Flex system NEW QUESTION 46Your customer used to manage their HPE 3PAR arrays using HPE OneView Now they have replaced these arrays HPE Primera.How does managing the new arrays compare to managing their old arrays?  HPE OneView offers additional functionalities for HPE Primera like CPG management  HPE OneView offers limited support tor HPE Primera because of the firmware differences  To manage HPE Primera using HPE OneView. a dedicated license is required  Management procedures and features are the same tor both types of the array NEW QUESTION 47Your customer is trying to grow a VMware duster using HPE OneView for VMware vCenter Server. They get an error and cannot proceed Which tool should you use to troubleshoot the problem?  HPE One View for VMware vCenter Server to verify if server profile template s property imported and registered  vCenter Server to verify if an OS Bund Plans property defined and has ESXi image uploaded  HPE OneView interface to import an existing cluster using the hypervisor cluster profile functionality.  ILO interlace of a given HPE Synergy compute node to verify whether this node is registered within HPE Oneview. NEW QUESTION 48Which statement about the SY480 Gen10 Plus Compute Module is true?  It cannot be mixed with Gen9 compute modules in the same frame.  It supports 8 memory channels and memory DIMMs of up to 256GB.  It only supports NVDIMM Persistent Memory.  It supports “3rd Gen AMO EPYC Server Processors with 64 cores. NEW QUESTION 49Match each HPE Synergy logical component with the definition. NEW QUESTION 50Refer to the exhibit.Which statement about this logical interconnect group is true?  The master modules are located in the interconnect bays 2 and 5  For the given downlink speed, the maximum number of frames is reached  Both master modules are located in the same HPE S ynergy frame  To use interconnect bay set 3, all compute nodes must be half-height  Loading … To prepare for the HP HPE0-S60 certification exam, candidates should have a deep understanding of HPE compute solutions technologies and architectures. They can also take advantage of HPE training courses, practice exams, and study materials to prepare for the exam. Passing the HP HPE0-S60 exam will help candidates enhance their career opportunities and demonstrate their expertise in HPE compute solutions to potential employers.   Latest 2024 Realistic Verified HPE0-S60 Dumps - 100% Free HPE0-S60 Exam Dumps: https://www.actualtests4sure.com/HPE0-S60-test-questions.html --------------------------------------------------- Images: https://blog.actualtests4sure.com/wp-content/plugins/watu/loading.gif https://blog.actualtests4sure.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2024-01-23 14:29:13 Post date GMT: 2024-01-23 14:29:13 Post modified date: 2024-01-23 14:29:13 Post modified date GMT: 2024-01-23 14:29:13