This page was exported from Actual Test Materials [ http://blog.actualtests4sure.com ] Export date:Wed Dec 25 19:28:48 2024 / +0000 GMT ___________________________________________________ Title: 2024 AD01 Premium Files Test pdf - Free Dumps Collection [Q78-Q100] --------------------------------------------------- 2024 AD01 Premium Files Test pdf - Free Dumps Collection Get ready to pass the AD01 Exam right now using our Blue Prism Developer Exam Package Blue Prism AD01 exam is an essential certification for professionals looking to advance their career in the field of Robotic Process Automation (RPA). It is designed to test the skills and knowledge of individuals in developing and maintaining Blue Prism solutions. This accreditation is recognized globally and demonstrates the ability to work with Blue Prism's RPA platform.   Q78. Consider the following process flow:Decision “A” properties are:Decision “B” properties are:Decision “C” properties are:What will happen when the process runs?  The flow will pass through calculation stage “A”  The flow will pass through calculation stage “B”  The flow will pass through calculation stage “C”  An exception will be thrown Q79. Consider the following flow within an Object Studio action:The developer of this flow found that writing some credentials to the target application sometimes failed with an exception even though the element exists on the screen. He found that simply catching the exception, waiting for 2 seconds and then retrying fixed the problem.What problems do you see within the flow” (select 2 responses)  A block has not been placed around the Write stage and the Recover stage, meaning the credentials action could be unnecessarily retried if another stage further into this action throws an exception.  There is a potential for an infinite loop if the ‘Credentials’ stage keeps throwing an exception for some unforeseen reason.  The credentials stage is a read stage not a write stage  There is not a Resume stage following the timeout of the Wait stage Q80. Which of the following stages can be found in BOTH the Object Studio and the Process Studio” Select the TWO correct responses.           In Blue Prism, certain stages can be found in both Object Studio and Process Studio. These stages are:* Read Stage (Option C): This stage is used to read data from elements and variables. It is available in both Object Studio and Process Studio.* Write Stage (Option D): This stage is used to write data to elements and variables. It is also available* in both Object Studio and Process Studio.The other stages listed in the options are specific to either Object Studio or Process Studio, but not both.ReferencesRefer to the Blue Prism documentation and training materials which outline the stages available in Object Studio and Process Studio.Q81. A process contains only 4 stages Study the following process flow:The data Item Result’ is a number data item with an initial value of 2.The calculation stage is configured as follows:Following the execution of the Perform Calculation stage, which of the following is true?  The data item Result will contain 3  The data item Result will contain 5  The process will throw an exception  None of these statements are correct Q82. Examine the following process flow:The Orders Collection contains the following dataThe Saved Quantity Data Item is configured as a number with the initial value 0.The Loop Orders stage is configured to loop though the Orders collection.The Get Quantity stage is configured as follows:What will the data item Saved Quantity contain after the execution of the page?  4  5  1  19 Q83. Which area of Blue Prism would you find application logic and rules?  Application Modeller  Object Studio  Process Studio  Application Logic area of System Manager Q84. Which of the following indicates a case in a Work Queue is waiting to be worked?A)B)C)D)C  Option A  Option B  Option C  Option D Q85. Examine the following Blue Prism Process diagram:The ‘Retry Limit’ data item is configured as a number data item, and has an initial value of 3. The ‘Retry Count* data item is configured as a number data item, and has an initial value of 0. The ‘Count’ Calculation stage increases the value of the ‘Retry Count’ data item by 1. The ‘Retry? Decision stage contains logic to prevent more than 3 attempts What is wrong with the current configuration?  The Resume stage must also be within the exception block  Sub-pages should not have retry logic Exception handling should be in the Object layer rather than in the Process  The retry loop logic shown in the image is incorrect because it uses multiple action stages There should be a retry loop around every action  The retry loop logic does not include any actions after the resume stage to ensure the application is ready to try the ‘Search Screen – Perform Search’ Action again * Understanding the Diagram:* The diagram shows a retry loop where the process attempts to perform a search, read results, and handle exceptions by retrying up to 3 times.* ‘Retry Limit’ is set to 3, and ‘Retry Count’ starts at 0 and is incremented by 1 in each retry attempt.* Analyzing the Logic:* Option A: The Resume stage should resume the process outside the exception block, which is correct.* Option B: Exception handling in the process layer is valid; it does not have to be exclusively in the object layer.* Option C: Each action does not need an individual retry loop; the overall block retry is acceptable.* Option D: This option highlights a missing step. After handling an exception and before retrying, the application needs to be reset or ensured it is ready to retry the ‘Search Screen – Perform Search’ action.* Identifying the Issue:* The retry logic should include steps to ensure the application state is appropriate for another search attempt. This might include resetting fields, waiting for the application to be ready, or ensuring the previous error state is cleared.References:* Blue Prism Developer Documentation: Exception Handling and Retry Logic* Blue Prism Training Material on Process Flow and Exception HandlingQ86. Study the following image showing part of the flow within a process:What problems do you see with the process flow? (Choose two.)  There is a missing Recover stage on one of the routes through the flow.  There is a missing Resume stage on one of the routes through the flow.  The Retry Count is not being incremented for each retry.  If an exception is thrown in the Cancel Reservation page and is allowed to bubble up to be caught by the Recover stage, the Create Reservation action won’t be retried. Explanation/Reference:Q87. Study at the following diagram which is an extract from a sub-page of a process being tested in Process Studio:There are no breakpoints in the “Access Customer Account” subpage however there is an error.What will happen if you choose to step out (SHIFT+ F11) when debugging the process?  The process will work all stages in the “Access Customer Account page until the error is thrown and then focus would move to the breakpoint at “Get Customer Details” stage.  The process will work all stages in the ‘Access Customer Account1 page until the error is thrown and then focus would move to the “Recover 1 stage  The process will work all stages in the “Access Customer Account’ page until the error is thrown and then focus would move to the stage containing the error on the “Access Customer Account” page,  The process will work all stages in the “Access Customer Account” page until the error is thrown and then focus would move to the “Exception 1 stage. Q88. Which of the following Work Queue icons indicates a case is waiting to be worked?         * Understanding Work Queue Icons in Blue Prism:* Each work queue icon in Blue Prism represents a different status of a work queue item.* Icons and Their Meanings:* Option A (Checkmark): This indicates that the item has been completed successfully.* Option B (Flag): This icon typically represents an item that is waiting to be worked on or is flagged for attention.* Option C (Lock): This indicates that the item is locked and cannot be processed.* Option D (Three Dots): This icon represents a case that is currently being worked on by a digital worker.* Conclusion:* The icon that indicates a case is waiting to be worked is Option B (flag).References:* Blue Prism Developer Documentation: Work Queue Icons and Status Indicators* Blue Prism Training Material on Work Queue ManagementQ89. Study the following Process flow:The Process flow is intended to test the value of the Input data item to determine if it falls within a range of numbers, and then assign a value as an output. The number ranges are defined as between 1 to 100, between101 to 200, and anything outside these ranges.The Calculation stages will set the value of the Result data item to 1, 2 or 3.To enable the Process flow to work correctly, what is the correct expression for the Choice stage branch named ‘Between 1 and 100’?  [Input] >= 1 AND [Input] <= 100  [Input] >= 1 AND <= 100  [Input] >= ‘1’ AND [Input] <= ‘100’  [Input] >= 1 [Input] < 100  [Input] BETWEEN 1 AND 100 Q90. The Stock Value Calculator application has been launched successfully by a Business Object named ‘Stock Value Calculator – Basic Actions’.A second Business Object named ‘Stock Value Calculator – Historic Values’ is used to interface with the Historic Values screen within the application.The Wait stage highlighted below has encountered an Internal Exception:Details of the Exception are provided below:What action is required to present this error occurring?  The Business Object ‘Stock Value Calculator – Historic Values’ needs to be attached to the Stock Value Calculator application  The Business Object ‘Stock Value Calculator – Historic Values’ must relaunch the Stock Value Calculator application  The Business Object ‘Stock Value Calculator – Basic Actions’ needs to be attached to the Stock Value Calculator application  The Business Object ‘Stock Value Calculator – Historic Values’ needs to activate the Stock Value Calculator application  The Business Object ‘Stock Value Calculator – Basic Actions’ needs to activate the Stock Value Calculator application Q91. Study at the following diagram which is an extract from a sub-page of a process being tested in Process Studio:There are no breakpoints in the “Access Customer Account” subpage however there is an error.What will happen if you choose to step out (SHIFT+ F11) when debugging the process?  The process will work all stages in the “Access Customer Account page until the error is thrown and then focus would move to the breakpoint at “Get Customer Details” stage.  The process will work all stages in the ‘Access Customer Account1 page until the error is thrown and then focus would move to the “Recover 1 stage  The process will work all stages in the “Access Customer Account’ page until the error is thrown and then focus would move to the stage containing the error on the “Access Customer Account” page,  The process will work all stages in the “Access Customer Account” page until the error is thrown and then focus would move to the “Exception 1 stage. Q92. Which of the following indicates a case has been worked successfully in a Work Queue?B)C)D)  Option A  Option B  Option C  Option D Q93. Please refer to the exhibitAn automation Start Up page has been created to launch and login to the Blue Prism Portal. The page has no Input or Output Parameters The page is run but causes an Exception What is the cause?  The Username and Password Data Items contains no hard-coded credentials  The BP Portal. Go to LMS action should be inside the Login Block  There is no action to retrieve the credentials from Credential Manager  The BP Portal Launch action should have a retry loop * Credential Retrieval:* The automation start-up page requires actions to retrieve the credentials from the Credential Manager to log in to the Blue Prism Portal.* Cause of Exception:* The exception is likely caused because there is no action to retrieve the username and password* from the Credential Manager, leading to missing or incorrect credentials.* Steps to Fix:* Ensure that an action is included to retrieve the credentials from the Credential Manager before attempting to log in.References:* Blue Prism documentation on using the Credential Manager and best practices for secure credential handling.Q94. Please refer to the exhibit.A Developer has used the Win32 mode lo spy the login window and the Region mode to spy the Username field of a Windows-based application.Using the Navigate stage, the developer would like to* Bring the application screen to bring it foreground* Send a ‘Global Mouse Click Centre’ command to the center of the username field* Use Global Send Keys to populate the username fieldHow should the navigate stage be configured?         * Understanding the Requirements:* The developer needs to perform the following actions using the Navigate stage:* Bring the application screen to the foreground.* Send a ‘Global Mouse Click Centre’ command to the center of the Username field.* Use Global Send Keys to populate the Username field.* Steps to Achieve the Requirements:* Bring the application to the foreground: This can be done using the ‘Activate Application’ action on the ‘Login Window’.* Send a ‘Global Mouse Click Centre’ command: This can be done by selecting the ‘Global Mouse Click Centre’ action on the ‘Username’ element.* Use Global Send Keys to populate the Username field: This can be done by selecting the‘Global Send Keys’ action on the ‘Username’ element.* Analyzing the Options:* Option A:* Launch action on the ‘Login Window’: Correct for bringing the application to the foreground but not suitable for already running applications.* Click Window Centre on ‘Login Window’: Not the best approach for focusing on a specific element.* Global Send Keys on ‘Username’: Correct for sending keys but requires prior focus on the Username field.* Option B:* Activate Application on the ‘Login Window’: Correct for bringing the application to the foreground.* Global Mouse Click Centre on ‘Username’: Correct for clicking the center of the Username field.* Global Send Keys on ‘Username’: Correct for sending keys to the Username field.* Option C:* Activate Application on the ‘Login Window’: Correct for bringing the application to the foreground.* Global Mouse Click Centre on ‘Username’: Correct for clicking the center of the Username field.* Global Send Keys on ‘Username’: Correct for sending keys to the Username field.* Option D:* Attach action on the ‘Login Window’: Not necessary for bringing the application to the foreground if it is already running.* Global Mouse Click Centre on ‘Username’: Correct for clicking the center of the Username field.* Global Send Keys on ‘Username’: Correct for sending keys to the Username field.* Conclusion:* The correct configuration is Option C because it uses:* ‘Activate Application’ action to bring the application to the foreground.* ‘Global Mouse Click Centre’ action to click the center of the Username field.* ‘Global Send Keys’ action to populate the Username field.References:* Blue Prism Developer Documentation: Navigate Stage and Actions* Blue Prism Training Material on Spying Modes and Application InteractionQ95. Examine the flow below:An error has been encountered on Page 1 and the exception has bubbled up to be recovered in the Recoverd stage The Yes’ path has been taken from the “Throw new Exception?” decision stage. Consider the Throw Exception stage properties below:How should the properties be configured for the Process to throw a new Business exception, i.e. a different exception to the one encountered in Page?  Configure ExceptionType() in the Exception Type field and ExceptionDetail() in the Exception Detail field. Leave the Preserve the type and detail of the current exception checkbox un-ticked.  Tick the Preserve the type and detail of the current exception checkbox. Leave the Exception Type and Exception Detail fields blank  Leave the Exception Type field blank and type “Business Exception” in the Exception Detail field.  Type Business Exception in the Exception Type field and type a custom message in the Exception Detail field. Q96. A Developer is unable to pass Collection data as an Input Parameter because the Collection is not visible under available Data Items What is the reason for this issue?  The referenced Collection is not set to global  There is a block surrounding the Collection  There are more than four fields in the Collection  The Collection fields are not defined * Understanding Input Parameters and Collections:* In Blue Prism, collections can be passed as input parameters to actions or processes if they are correctly defined and visible.* Possible Reasons for Collection Not Being Visible:* Option A: Collections must be set to global (accessible on all pages) to be used as input parameters. If the collection is not set to global, it will not be available under the available data items.* Option B: Surrounding a collection with a block does not affect its visibility as an input parameter.* Option C: The number of fields in a collection does not impact its ability to be passed as an input parameter.* Option D: Undefined collection fields would cause issues in using the collection but would not prevent it from being visible.* Conclusion:* The reason the developer is unable to pass the collection data as an input parameter is because A.The referenced Collection is not set to global.References:* Blue Prism Developer Documentation: Collections and Global Data Items* Blue Prism Training Material on Data Item Scope and VisibilityQ97. Study the process flow below:The outputs for the Get Next Case are configured below:What is the correct configuration of the Expression in the “Case-Returned” decision stage?         Q98. A Blue Prism solution interfaces with an internet application called HappyWeb There is a test website available for development, and a training site available for user acceptance testing, and there is the production she available for processing live cases in HappyWeb.Which of the following is true?  All development and testing MUST be done using the production site. This is because the test and training websites might not mirror production exactly.  A local text file should be used to easily configure the details of the HappyWeb website to be used in each Blue Prism environment.  An Environment variable should be used to store the HappyWeb URL.  Three different versions of object that launches the HappyWeb website will need to be created and maintained, one for each environment. Q99. Which of the following can you perform in Control Room? (select all that apply)  Refresh a Work Queue  Create a Work Queue  Encrypt a Work Queue  Rename a Work Queue Explanation/Reference:Q100. Please refer to the exhibits.This is a detail of a Process sub-page* Sign Up Dale Current Date and Expiry Date Dala Hems are of the Date data type* Status and Output Data Items are of the Text’ data type.What is the output of this logic when the page is executed till its End stage’  Subscription Status = Expired. Expiration Date = 04-07-2023  Internal Error at the Decision stage as > function cannot be used for dates  Internal Error at the Calc3 stage as a date cannot be stored in a Text Data Item  Subscription Status = Active; Expiration Date = 04-07-2023 * Data Items and Types:* Sign Up Date: 04-05-2023 (Date data type)* Current Date: 13-06-2023 (Date data type)* Expiry Date: 04-07-2023 (Date data type)* Status: Text data type* Output: Text data type* Decision Stage:* The decision checks if Current Date > Expiry Date.* 13-06-2023 is not greater than 04-07-2023, so the decision evaluates to No.* Calc1 and Calc3 Execution:* Since the decision is No, Calc1 and Calc3 are executed.* Calc1 is not shown, but it must set Status to something other than “Expired” (possibly “Active”).* Calc3 concatenates Status and Expiry Date to form the final output.* Expected Output:* If Calc1 sets Status to “Active”, Calc3 will produce the output:* Subscription Status = Active; Expiration Date = 04-07-2023Final Output:* Given the logic and data provided, if Calc1 does not change Status from “Expired” (it wasn’t executed due to decision No path):* Subscription Status = Expired. Expiration Date = 04-07-2023* If the decision path was intended to show Expired status, then:* Subscription Status = Expired; Expiration Date = 04-07-2023.References:* Blue Prism documentation on decision stages and data type handling in expressions. Loading … The AD01 certification exam is a rigorous and challenging test that requires a deep understanding of Blue Prism's RPA technology. AD01 exam is designed to test your knowledge of the platform's core concepts, features, and functionalities. It consists of multiple-choice questions, and you will need to score at least 70% to pass. AD01 exam is available online and can be taken from anywhere in the world. The Blue Prism AD01 certification is a globally recognized credential that demonstrates your expertise in RPA development and can help you stand out in a competitive job market.   Master 2024 Latest The Questions Blue Prism Developer and Pass AD01 Real Exam!: https://www.actualtests4sure.com/AD01-test-questions.html --------------------------------------------------- Images: https://blog.actualtests4sure.com/wp-content/plugins/watu/loading.gif https://blog.actualtests4sure.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2024-12-05 10:14:17 Post date GMT: 2024-12-05 10:14:17 Post modified date: 2024-12-05 10:14:17 Post modified date GMT: 2024-12-05 10:14:17