This page was exported from Actual Test Materials [ http://blog.actualtests4sure.com ] Export date:Wed Jan 22 4:42:40 2025 / +0000 GMT ___________________________________________________ Title: 2025 Latest CLAD dumps - Instant Download PDF [Q27-Q49] --------------------------------------------------- 2025 Latest CLAD dumps - Instant Download PDF Updated Verified CLAD Downloadable Printable Exam Dumps NEW QUESTION 27What is the value in Shift Register Answer after the following code has executed?  16  24  32  10 Explanation/Reference:NEW QUESTION 28Which of the following functions assembles Cluster elements by their owned labels?  Unbundle by Name  Unbundle  Bundle by Name  Bundle NEW QUESTION 29Which of the following illustrates an advantage of a global variable over a local variable?  A global variable can pass data between two independent VIs runningsimultaneously  Only the global variable can pass array data, local variables cannot  Global variables follow the dataflow model, and therefore cannot cause raceconditions  Global variables do not require owned labels to operate NEW QUESTION 30Which of the following apply to Property Nodes? (Choose all apply)  Property Nodes allow attributes of front panel objects to be programmaticallymanipulated.  Property Nodes can be used to update the values contained in a front panelobject.  More than one Property Node can be used for a single front panel object.  Property Nodes contained in aSubVI will always cause the front panel to beloaded in memory. NEW QUESTION 31What is the value in XOR Result after the following code has executed?  0  1  True  False NEW QUESTION 32Which of the following cannot be used to transfer data?  Local variables  Queues  Semaphores  Notifiers NEW QUESTION 33Which of the following is the best method to update an indicator on the front panel?  Use a Value property node  Wire directlyto the indicator terminal  Use a local variable  Use a functional global variable NEW QUESTION 34How do you document a VI so that the description appears in the Show Context Help popup window?  Use the VI Properties Documentation window  Type in the Show Context Help window  Create a free label on the front panel  Edit the LabVIEW help files NEW QUESTION 35You have a control on the front panel of a VI and you need to modify one of its properties at run time.Which of the following is the best approach you would take?  Create an implicit property node and select the property to modify  Create a control reference, pass the reference to a property node and select the property to modify  Create a linked shared variable and select the property to modify the property  Create a local variable and select the property to modify NEW QUESTION 36What is the result in Array after the following code has executed?  A 1-D array of {1, 4, 3, 2, 1, 0}  A 1-D array of {1, 8, 0, 1, 2, 3, 4, 6, 2}  A 1-D array of {1, 4, 3, 2, 1, 0, 8, 6, 2}  A 1-D array of {1, 8, 0, 1, 2, 2, 9} NEW QUESTION 37Which of the following statements is true about the iteration terminal?  It returnsthe number of times the loop has executed  It returns the number of times the loop has executed, plus one  It returns the number of times the loop has executed, minus one  It returns a constant number NEW QUESTION 38You are inputting data that represents a circle. The circle data includes an x position, ay position, and a radius. All three pieces of data are double-precision. In the future, you might need to store the color of the circle, represented as an integer. How should you represent the circle on your front panel window?  Three separate controls for the two positions and the radius.  A cluster containing all of the data.  A type definition containing a cluster.  An array with three elements. NEW QUESTION 39The DAQmx task is set to acquire at a rate of 1000 Hz.Which VI Snippet acquires and plots only the maximum value for each set of 1000 samples, for a period of5 seconds?A:B:C:D:  Option A  Option B  Option C  Option D NEW QUESTION 40Which of the following accurately describes the output that results from execution of the following loop?  The last three values from the DAQ Assistant will be displayed.  A running average of all measurements will be displayed.  An average of the last four measurements will be displayed.  None of the above NEW QUESTION 41What is the value in Shift Register Answer after the following code has executed?  16  24  32  10 NEW QUESTION 42In what instance would you use the Probe tool rather than Highlight Execution?  To see the flow of data  To see the value of a wire in real-time  To look into a SubVI, as the process is running  To slowdown the VI and show data values in wires ExplanationNEW QUESTION 43Clicking on the _________ button allows you to bypass a node in the Block Diagram without single-stepping through the node.  Step Into  Step Over  Step Out  Step Through NEW QUESTION 44Which of the following allows you to plot any set of points, evenly distributed or not?  Waveform Graph  Waveform Chart  XY Graph  Both A and C. NEW QUESTION 45What mechanical action of a Boolean would you use to mimic a button on a Windows dialog?  Switch Until Released  Switch When Released  Latch Until Released  Latch When Released NEW QUESTION 46Which of the graphs below matches the output in the Waveform Graph indicator after the following code has executed?  Option A  Option B  Option C  Option D NEW QUESTION 47Which of the following statements regarding the index of Arrays are NOT true?  The index is used to access a particular element of an Array.  The index ranges from 1 to n.  A 2-D Array has both a column index and a row index.  The index ranges from 0 to n-1. NEW QUESTION 48You customize a control, select Control from the Type Def. Status pull-down menu, and save the control as a .ctl file. You then use an instance of the custom control on your front panel window. If you open the .ctl file and modify the control, does the control on the front panel window change?  Yes  No NEW QUESTION 49What VI is typically used to terminate an Error Cluster wire and to display any error message?  Merge Errors  One Button Dialog/Two Button Dialog  Generate Front Panel Activity  Simple Error Handler  Loading … NI CLAD Exam Syllabus Topics: TopicDetailsTopic 1Usingbasic functions to create a simple Acquire-Analyze-Visualize application Create SubVIs to increase readability and scalability of VIsTopic 2Group related data by creating a cluster to improve data organization and VI readability Choose appropriate code asaSubVI sourceTopic 3Recognize data types on the block diagram from terminals and wires Configure the subVI connector pane using best practicesTopic 4Create, manipulate, analyze,and use cluster data in common scenarios Recognize data typeson the front panelTopic 5Troubleshooting by identifying and correctingthe cause of a broken arrow or incorrect data Retain data in shift registersTopic 6Determining the last value output Navigating LabVIEW help to get more information about inputs, outputs, andfunctionsTopic 7Create Type Defs and use Type Defs in multiple places Use libraries and appropriate types of folders For more info visit: CLAD Exam Reference   The Ultimate NI CLAD Dumps PDF Review: https://www.actualtests4sure.com/CLAD-test-questions.html --------------------------------------------------- Images: https://blog.actualtests4sure.com/wp-content/plugins/watu/loading.gif https://blog.actualtests4sure.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2025-01-10 13:56:23 Post date GMT: 2025-01-10 13:56:23 Post modified date: 2025-01-10 13:56:23 Post modified date GMT: 2025-01-10 13:56:23